Galvanic skin response sensor GSRsens
Galvanic skin response sensor GSRsens
Manufacturer code:
007-0-231
Compare
Galvanic skin response sensor, NeoSens‑compatible.
In stock
Overview
Specifications
Standard set
Galvanic skin response sensor GSRsens consists of an amplifier block and two electrodes connected to the amplifier block. The amplifier block is designed for connection to NeoSens-compatible connectors of bioelectric signal amplifiers such as NVX136 or similar.
Getting started
The electrodes are attached with a fixing strap to the palmar surface of the fingers of one hand on the middle phalanges of the index and middle or ring fingers to avoid contact between the electrodes.
| Registered parameter | galvanic skin response |
| Channels | 1 |
| Number of lead cables | 2 |
| Square of sensor conductive surface | > 4 cm2 |
| Material of sensor conductive surface | Ag/AgCl |
| Transfer characteristic form | linear dependence of output voltage on conductivity |
| Transmission coefficient | 25 mV/µS |
| Operating range | 0.5 to 80 µS |
| Measurement accuracy | 10% |
| Frequency range | 0 to 10 Hz (-3dB) |
| Noise | < 3.5 µV p‑p |
| Offset voltage | < ±2.5 mV |
| Reference voltage | 0.5V |
| Supply voltage | 5V (±5%) |
| Consumption current | < 30 mA |
| Connector for connecting the lead cable | TouchProof 1.5 mm (DIN 42 802‑BU) x 2 |
| Сable length | 1.2 m |
| Connector for connecting to an amplifier | NeoSens‑compatible |
-
GSRsens amplifier block,
-
GSR electrodes for GSRsens - 2 pcs.,
-
cables with button connection for electrodes,
-
User Manual.
EEG amplifier
Electrode cap compatibility
Compact-neuro
Neurotech
Custom
EEGA-21/26 "Encephalan-131-03"
Medicom-mtd
Custom
MBN24
MBN
Custom
Medelec
Oxford Inc.
Custom
Mitsar-EEG-03/35-201
MITSAR
Custom
Mitsar-EEG-05/70-201
MITSAR
Custom
Mitsar-EEG-10/70-201
MITSAR
Custom
Mitsar-EEG-202 (24+8)
MITSAR
Custom
Mitsar-EEG-202 (31+1)
MITSAR
Custom
Mitsar-EEG-202 (31+8)
MITSAR
Custom
Neuro KM
Statokyn
Custom
Neurocartograph-01-MBN
MBN
Custom
Neurocartograph-02-MBN
MBN
Custom
Neurocartograph-03-MBN
MBN
Custom
Neurofax EEG 1200
Nikon Kohden
Custom
Neurofax EEG 1212
Nikon Kohden
Custom
Neurofax EEG 1221
Nikon Kohden
Custom
Neurofax EEG 9110
Nikon Kohden
Custom
Neurofax EEG 9210
Nikon Kohden
Custom
Neuron-Spectrum-1
Neurosoft
Custom
Neuron-Spectrum-2
Neurosoft
Custom
Neuron-Spectrum-3
Neurosoft
Custom
Neuron-Spectrum-4/EPM
Neurosoft
Custom
Neuron-Spectrum-4/P
Neurosoft
Custom
Neuron-Spectrum-5
Neurosoft
Custom
Neuron-Spectrum-61
Neurosoft
Custom
Neuron-Spectrum-62
Neurosoft
Custom
Neuron-Spectrum-63
Neurosoft
Custom
Neuron-Spectrum-64
Neurosoft
Custom
Neuron-Spectrum-65
Neurosoft
Custom
Neuron-Spectrum-AM
Neurosoft
Custom
Neuropolygraph
Neurocor
Custom
NeuroScope NS400
Biola
Custom
NeuroScope NS400A
Biola
Custom
Nicolet EEG v32 (CareFusion)
Natus
Custom
Nicolet One
Viasys
Custom
NVX136
Medical Computer Systems
Custom
NVX24
Medical Computer Systems
Custom
NVX36
Medical Computer Systems
Custom
NVX52
Medical Computer Systems
Custom
Catalogue MCScap EEG accessories