16‑channel wireless EEG amplifier with electrode cap with dry electrodes MCScap‑DrP1.
Size
In stock
Price:
1 200
quantity
Add to cart
Overview
Specifications
Standard set

System NeoRec cap 16 DRY is the 16-channel model of the NeoRec cap DC mobile EEG (hereinafter NeoRec cap), including an EEG amplifier NeoRec 16 and the DRY cap for NeoRec 16 electrode cap.

NeoRec cap DC mobile EEG – is a mobile electroencephalograph for non-invasive recording of electrical activity of the brain.

NeoRec cap intended for use both in a specially equipped room and outside, including on the street. But it is necessary to exclude the influence of strong electromagnetic interference on the device during operation.

NeoRec cap can be used for education, research and development in EEG, neuro-computer interfaces (brain-computer interface, direct neural interface, brain interface), bio-feedback (BCI), neuromarketing, neurogaming, brain fitness.

NeoRec cap intended to record EEG and 3D acceleration events to files of different formats (EDF+ 16 bit, BDF+ 24 bit, GDF 32 bit) or transmit it online via stream LSL (Lab Streaming Layer) for analyze by third-party software as MATLAB / EEGLAB, OpenViBE etc.

For developers of their own software, interaction via API is provided (https://github.com/mcsltd/NB2CppDemo).

EEG amplifier NeoRec 16 is a 16‑channel wireless EEG amplifier with a built-in accelerometer. NeoRec 16 is designed to record EEG and other bioelectrical signals with wireless real-time data transfer to a PC. The amplifier is powered by a built-in battery.

Electrode cap DRY cap for NeoRec 16 is the textile cap with pre-installed dry passive Ag/AgCl MCScap‑DrP1  electrodes with common connector for NeoRec 16 amplifier. The ear electrode is connected to the common connector through the TouchProof 1.5 mm (DIN 42 802‑BU) connector for the possibility of replacing it with another electrode or signal source. The electrode cap is designed for non-invasive registration EEG when used with the EEG amplifier. The electrode cap is a reusable device.

  • Answers to frequently asked questions about installing and using NeoRec cap, connecting via API are published on the website in the section Questions and Answers - NeoRec cap.

EEG channels monopolar according to GND 16
Electrode impedance measurement range from 1 to 140 kOhm
Time of continuous work ≥ 15 hours
Offline data recording no
Wireless data interface BLE 4.2
Connector for connecting a cap/charger; ST60‑18P
Enclosure dimensions 68 х 38 х 16 mm
Weight of the amplifier 40 g
Recomended software NeoRec
Input dinamic range ±150 mV, ±300 mV
Accuracy of signal reproduction 1 %
Frequency range at -3 dB 0 to 430 Hz (at 1000 Hz sampling rate)
Sampling rate 125 Hz, 250 Hz, 500 Hz, 1000 Hz
Data resolution 24 bit
Noise (in operating range from 0.5 to 70 Hz) 2 μV p‑p
Input impedance more 1 GOhm
Events from internal smart accelerometer activity (4 steps of sensitivity); change orientation (turn by 60°);
Events from button press
Check of battery status yes, by charge/discharge counting
Charging of internal battery from +5V USB adapter, 500 mA
Time to fully charge the built-in battery ≤ 2.5 hours
Operating conditions from +10°С to +35°С
Ingress Protection IP54 (depending on spatial position and accessories)
Useful life 2 year
Safety IEC 60950-1
data format proprietary, with the ability to save in EDF+, BDF+, GDF, EEG formats by software
Model of electrode cap DRY cap for NeoRec 16
Electrode MCScap‑DrP1
Model of textile cap MCScap textile cap
Cable length 5 cm
Location of the output of the electrode cable from the cap back of the head
Marking of the textile cap yes
Marking of the electrodes yes
ear electrode with TouchProof 1.5 mm connector MCScap‑DrP1 - 1 pc.
Weight of EEG cap < 350 g
Connector type ST40X‑18S
Number of EEG electrodes 16 + 1 removable ear electrode
Electrode positions FP1, FP2, O1, O2, F3, F4, C3, C4, P3, P4, T7, T8, Fz, Cz, Pz, GND, AUX
Additional pins AUX (1*) - built-in connector TouchProof 1.5 mm (DIN 42 802‑BU) for connecting an ear or other additional electrode.

  • EEG amplifier NeoRec 16,

  • Electrode cap,

  • USB cable for charging NeoRec 16,

  • User Manual,

  • Plastic box.

Download and install the latest version of the NeoRec software from the manufacturer's website https://mks.ru/en/support/neoreccap/ .

EEG amplifier
Electrode cap compatibility
Compact-neuro Neurotech
Custom
EEGA-21/26 "Encephalan-131-03" Medicom-mtd
Custom
MBN24 MBN
Custom
Medelec Oxford Inc.
Custom
Mitsar-EEG-03/35-201 MITSAR
Custom
Mitsar-EEG-05/70-201 MITSAR
Custom
Mitsar-EEG-10/70-201 MITSAR
Custom
Mitsar-EEG-202 (24+8) MITSAR
Custom
Mitsar-EEG-202 (31+1) MITSAR
Custom
Mitsar-EEG-202 (31+8) MITSAR
Custom
Neuro KM Statokyn
Custom
Neurocartograph-01-MBN MBN
Custom
Neurocartograph-02-MBN MBN
Custom
Neurocartograph-03-MBN MBN
Custom
Neurofax EEG 1200 Nikon Kohden
Custom
Neurofax EEG 1212 Nikon Kohden
Custom
Neurofax EEG 1221 Nikon Kohden
Custom
Neurofax EEG 9110 Nikon Kohden
Custom
Neurofax EEG 9210 Nikon Kohden
Custom
Neuron-Spectrum-1 Neurosoft
Custom
Neuron-Spectrum-2 Neurosoft
Custom
Neuron-Spectrum-3 Neurosoft
Custom
Neuron-Spectrum-4/EPM Neurosoft
Custom
Neuron-Spectrum-4/P Neurosoft
Custom
Neuron-Spectrum-5 Neurosoft
Custom
Neuron-Spectrum-61 Neurosoft
Custom
Neuron-Spectrum-62 Neurosoft
Custom
Neuron-Spectrum-63 Neurosoft
Custom
Neuron-Spectrum-64 Neurosoft
Custom
Neuron-Spectrum-65 Neurosoft
Custom
Neuron-Spectrum-AM Neurosoft
Custom
Neuropolygraph Neurocor
Custom
NeuroScope NS400 Biola
Custom
NeuroScope NS400A Biola
Custom
Nicolet EEG v32 (CareFusion) Natus
Custom
Nicolet One Viasys
Custom
NVX136 Medical Computer Systems
Custom
NVX24 Medical Computer Systems
Custom
NVX36 Medical Computer Systems
Custom
NVX52 Medical Computer Systems
Custom

Did not find your amplifier? Contact us: +7 499 404-31-41, shop@mcscap.ru or use feedback form
Catalogue MCScap EEG accessories
Download